Cause of failure:
Safety fuse
Controller output loop
The light bulb damage
Tools used for maintenance:
multimeter
Process of fault inspection:
1. Check whether the fuse of electrical junction box F35 is blown;
2. Check whether pins 1 and 2 of the combined switch X102/1 are 24V voltage;
3. Check whether 24V power supply is output when Pin 1 and Pin 4 turn on the turn signal of the second plug of Nano controller;


Cause of failure:
Taillight joint is loose
Bad contact with junction box
Safety fuse
Maintenance tools:
multimeter
Process of fault inspection:
1. Check whether the wiring harness plug of the failed lamp is loose and corroded;
2. Check whether the insert block number in the distribution box corresponds to the distribution box;
3. Check whether the safety of distribution box F19 and F21 is fused;